ISO 10816 Series Overview

ISO 10816 is a multi-part standard covering vibration measurement and evaluation of non-rotating parts of machines. Key parts:

  • ISO 10816-1: General guidelines — measurement locations, measuring quantities, and evaluation criteria framework
  • ISO 10816-3: Industrial machines with nominal power above 15 kW and nominal speeds 120–15,000 RPM — the most widely applied part in industrial plants
  • ISO 10816-7: Rotodynamic pumps — specific limits for centrifugal, mixed-flow, and axial pumps
  • ISO 20816: Updated series (supersedes ISO 10816 in some parts) — same zone concept with revised limits

Machine Groups (ISO 10816-3)

ISO 10816-3 divides machines into four groups based on rated power and mounting:

GroupMachine typePower
Group 1Large rotating machines, directly coupled to rotating loads (turbines, compressors)>300 kW, or 15 kW on special support
Group 2Medium-sized machines, generally electric motors and pumps15–300 kW
Group 3Pumps with multivane rotary impellers, installed on separate foundations>15 kW
Group 4Pumps with multivane rotary impellers, installed on common foundations with driver>15 kW

Zone Limits — ISO 10816-3 (mm/s RMS velocity)

ZoneGroup 1 — RigidGroup 1 — FlexibleGroup 2 — RigidGroup 2 — Flexible
A/B boundary2.33.52.33.5
B/C boundary (Alert)4.57.14.57.1
C/D boundary (Danger)7.111.27.111.2

"Rigid mounting" = machine bolted to a stiff concrete foundation. "Flexible mounting" = machine on anti-vibration mounts or flexible structures.

Zone Descriptions and Actions

ZoneDescriptionAction
ANew or recently overhauled machine in excellent conditionNo action — continue routine monitoring
BAcceptable for unrestricted long-term operationMonitor — investigate any upward trend
CNot suitable for continued long-term operation — marginal conditionAlert — schedule inspection; increase monitoring frequency
DSufficiently severe to cause damage — operate at operator's riskStop machine or reduce load; immediate inspection required

ISO 10816-7 — Pump Specific Limits

For centrifugal pumps in industrial use, ISO 10816-7 defines limits based on rated power and speed. Key values for pumps >15 kW at 600–3,600 RPM on rigid foundations:

ZonePump class I (foundation-mounted)Pump class II (integrated unit)
A/B boundary2.3 mm/s3.5 mm/s
B/C boundary4.5 mm/s7.1 mm/s
C/D boundary7.1 mm/s11.0 mm/s

Applying the Standards

The ISO zone limits are useful as a starting point for condition monitoring alarm setting. However, for machines with known baseline data, statistical alarm methods (baseline + N standard deviations) are more sensitive and should be used in conjunction with ISO limits.

For acceptance testing of newly installed or overhauled machines: the machine should be in Zone A or low Zone B when measured under normal operating conditions. A machine leaving the factory or repair workshop in Zone C should be rejected and investigated before acceptance.

ISO 10816 measures vibration velocity (mm/s RMS) in the frequency range 10–1,000 Hz. Bearing defect detection requires higher frequency analysis (1–20 kHz envelope analysis) — ISO 10816 limits do not capture early-stage bearing defects.