Free calculator

Compressed Air Leak Cost Calculator

Quantify the annual energy cost of compressed air leaks. Enter the leak orifice diameter (or select a leak severity class), system pressure, and energy cost to get an instant £/$ annual loss figure.

Key fact

A single 3 mm leak at 7 bar costs approximately £1,200–£1,800 per year in electricity (at UK average industrial rates). A typical manufacturing plant leaks 20–30% of its compressed air production. Ultrasonic leak detection surveys typically pay back in 1–3 months.

Leak cost calculator

Annual energy cost per leak
—
per year per leak
Leak flow rate—
Compressor power wasted—
Annual kWh wasted per leak—
Total cost (1 leak)—
⚠

Compressed air leak costs are calculated using the orifice flow equation at critical flow conditions. Actual costs vary with compressor specific power, load factor, and leak location. This figure provides a conservative estimate suitable for business case calculations.

Understanding compressed air leak costs

How are leaks costed?

The calculator uses the critical orifice flow equation for compressible gas flow. For a circular orifice at critical (choked) flow conditions — which applies at typical industrial pressures of 6–10 bar — the volumetric flow rate is:

Q (L/min) ≈ 0.0785 × d² × Pabs

where d is orifice diameter in mm and Pabs is absolute pressure in bar. The compressor power to produce this flow is then Q ÷ (specific power × 1000).

Leak size classification

ClassApprox. diameterFlow @ 7 barAnnual cost*
Pinhole0.5 mm~14 L/min~£150/yr
Small1 mm~55 L/min~£600/yr
Medium3 mm~500 L/min~£1,500/yr
Large6 mm~2,000 L/min~£6,000/yr
Very large12 mm~8,000 L/min~£24,000/yr

* Based on 6,000 hours/year, 18 p/kWh, specific power 7 kW/100 L/min

Detection methods

The gold standard for leak detection is ultrasonic leak detection — handheld ultrasonic detectors (e.g., UE Systems, SDT) can locate leaks at distances of 3–10 m during normal plant operation, without shutting down. A survey of a medium-sized plant (100 compressed air consumers) typically takes 4–8 hours and identifies 40–120 leak points.

See our full guide on compressed air leak detection methods and survey procedures.